Guide · Homeowners · 3 min read · Updated 17 November 2026
Misted Double Glazing: Repair the Glass or Replace the Window?
Short answer
Misting between the panes means the sealed unit's edge seal has failed. The fix is to replace the glass unit, which typically costs £90–£250 per unit and keeps your existing frame. Replace the whole window, from about £450–£900 for uPVC, if the frame is warped, rotten or insecure, many units have failed, or you want better performance. DIY demisting kits rarely give a lasting fix.
Why double glazing mists up
A double-glazed sealed unit is two panes of glass separated by a spacer bar around the edge, with the gap sealed and often filled with an inert gas such as argon. The spacer contains a desiccant that absorbs any moisture trapped during manufacture. Over time, the edge seal can break down through age, sunlight, frame movement, water sitting in the frame rebate or poor original manufacture.
Once the seal fails, moist air gets into the cavity. The desiccant soaks up what it can and then becomes saturated, after which condensation forms between the panes, especially on cold mornings or when the sun warms the glass. Mineral deposits can then leave a permanent cloudy film on the inner faces. The insulating gas also escapes, so the unit loses some thermal performance.
Condensation on the inside, outside or between
Where the moisture forms tells you a lot. Condensation on the room-side face is common in kitchens, bathrooms and bedrooms in cold weather and usually comes from high humidity indoors. Condensation on the outside face often happens on efficient windows on cool, clear mornings and is actually a sign the glass is insulating well. Neither of these means the unit has failed.
Condensation between the panes, which you cannot wipe away from either side, is the one that means the seal has gone. It will not fix itself, and it usually gets worse over time.
| Where it forms | Likely cause | What to do |
|---|---|---|
| Room side of the glass | High indoor humidity | Improve ventilation, use trickle vents and extractors |
| Outside face | Cool, clear nights on efficient glass | Nothing, it clears as the day warms |
| Between the panes | Failed edge seal | Replace the sealed unit |
| Around frame edges inside | Cold bridging or draughts | Check seals and fitting |
Replacing just the glass unit
If the frame is in good condition, replacing the sealed unit is the sensible, cost-effective fix. A glazier measures the unit, orders a new one to the same size, and on the fitting day removes the glazing beads, takes out the old unit, fits the new one on packers and refits the beads. Each unit takes well under an hour to swap once it arrives.
This is also a chance to upgrade. Replacement units can include a low-emissivity coating, warm-edge spacers and argon fill, so you may end up with better thermal performance than the original. Obscured, laminated, toughened or acoustic glass can be specified where needed. Glass in critical locations must still be safety glass under Approved Document K.
- Frame is sound, square and secure
- Only one or a few units have failed
- Locks, hinges and handles work properly
- You are happy with the window style
- You want to keep costs down
When to replace the whole window
Full replacement makes more sense when the problem is the frame rather than the glass. Warped or discoloured uPVC, rotten timber, corroded old aluminium without a thermal break, failing hinges that cannot be replaced and locks that no longer secure the window are all signs the window is near the end of its life. Fitting a new unit into a failing frame is money poorly spent.
If most of the units in the house are failing at once, it can also be worth comparing the cost of replacing all the glass with replacing the windows. Old windows often have weaker locks, poorer seals and lower thermal performance than modern ones. Replacement windows in England must be certified under Building Regulations, whereas a glass-only swap is generally treated as a repair.
Why DIY demisting rarely works
Demisting services and kits drill small holes in the glass, clean and dry the cavity, then seal the holes with plugs. This can improve the look for a while, but it does not repair the failed edge seal or restore the insulating gas, and the glass may still be stained by mineral deposits. In many cases the misting returns, and the drilled holes remain visible.
Removing and refitting glass units yourself is also not recommended. Units are heavy, edges can be sharp, and the unit has to sit on the right packers so the frame does not drop and the seal is not stressed. A professional glazier will do the job safely, quickly and with the right replacement specification, and old units can be taken away for disposal.
To get a quick, accurate price, note which windows are affected, roughly how big each pane is and whether it is on the ground floor or higher up. Photos showing the misting and the frame help a glazier judge whether a glass swap will work or whether the frame needs attention too. If several units have failed at the same time and the windows are of the same age, expect others to follow, so it can make sense to replace them together and save on repeat visits.
Questions people also ask
How much does it cost to replace a misted double glazing unit?
Typically £90–£250 per unit, depending on size, glass type and access. Small units with standard glass are at the lower end. Large units, toughened or laminated safety glass, acoustic or obscured glass, and windows on upper floors needing ladders or towers sit towards the top.
Is misted double glazing a problem?
It is mainly a performance and appearance issue rather than a safety one. The failed seal means the unit has lost some insulating value, and the misting usually gets worse and can stain the glass. Replacing the unit restores clear views and thermal performance without replacing the whole window.
Can the glass in a composite door be replaced?
Usually, yes. Many composite and uPVC doors have glazed panels held in with beads or a cassette, and the sealed unit can be swapped. Door glass must be safety glass, so the replacement will be toughened or laminated. Decorative designs can often be matched or upgraded.
Written and checked by the Windows and Doors team. Read our editorial policy.
More guides
How Much Do Replacement Windows Cost in the UK? 2026 Prices
A standard uPVC casement window typically costs £450–£900 supplied and fitted in the UK in 2026, while an aluminium casement costs £700–£1,400. Sash…
uPVC vs Aluminium vs Timber Windows: Which Is Best for You?
uPVC is the most affordable, at about £450–£900 per standard window, and needs little maintenance. Aluminium costs £700–£1,400, gives slim frames,…
Replacement Window Building Regulations and FENSA Certificates
In England, replacing windows and external doors is controlled work under Building Regulations. Installers registered with a competent person scheme…
How Much Does a New Front Door Cost in the UK? 2026 Guide
A composite front door typically costs £1,200–£2,400 supplied and fitted in the UK in 2026, including a multipoint lock, anti-snap cylinder and…